Buying guide
Commercial Dishwasher Buying Guide: Types and High vs Low Temp
Who this is for: Restaurant owners, kitchen managers and project teams choosing a dish machine for a new kitchen or replacing an existing one.
Short answer: Size the machine to the racks you must wash in your busiest hour: undercounter units for bars and small cafés, door-type machines for most full-service restaurants, and conveyor or flight-type machines for high-volume and institutional kitchens. Then choose high-temp (hot-water sanitizing with a booster heater) or low-temp (chemical sanitizing) based on your electrical service, ventilation and chemical costs. Confirm NSF/ANSI 3 listing, check ENERGY STAR models, and plan water, drain, power and any hood the local code requires before you order.
Machine types by racks per hour
Dish machines are compared by how many standard racks they can wash per hour. The published figure is a maximum under ideal conditions; real throughput is lower because staff load, scrape and unload between cycles. Size to your peak hour, not your daily average, and leave headroom.
| Type | Typical capacity | Best for | Space and install notes |
|---|---|---|---|
| Undercounter | About 20–40 racks/hour | Bars, cafés, small restaurants, glasswashing | Fits under a counter; simplest utilities |
| Door-type (stationary rack, pass-through) | About 50–70 racks/hour | Most full-service restaurants | Needs inlet and outlet dish tables; corner or straight layouts |
| Rack conveyor | Often 200 or more racks/hour, depending on length and tank count | High-volume restaurants, schools, hotels, institutions | Long footprint; larger utilities; often needs a hood or vapor control |
| Flight-type (rackless conveyor) | Usually rated in dishes per hour; the highest-capacity class | Hospitals, universities, large institutions | Engineered systems with the largest utility and space needs |
High-temp vs. low-temp sanitizing
A high-temperature machine sanitizes with a hot-water final rinse. Building hot water is not hot enough on its own, so the machine uses a booster heater, either built in or installed separately, to raise the rinse water to the required temperature. High-temp machines need no chemical sanitizer, and wares dry faster because they leave the machine hot, but they draw a large electrical load and release more heat and vapor.
A low-temperature machine sanitizes with a chemical sanitizer, commonly chlorine-based, injected into the final rinse. These machines usually cost less to buy, need less electrical capacity and add less heat to the room, but you pay for sanitizer on an ongoing basis, wares dry more slowly, and some chemicals are hard on certain materials. Many low-temp machines are supplied by chemical companies as part of a chemical program.
The FDA Food Code sets minimum hot-water final-rinse temperatures for hot-water sanitizing machines and minimum concentration, temperature and contact requirements for chemical sanitizing. We do not quote specific numbers here: the machine's data plate states its own operating requirements, and your local health department, which may have adopted a different edition of the Food Code, governs. Plan how staff will verify sanitizing, for example with sanitizer test strips or a temperature-measuring device.
| High-temp (hot water) | Low-temp (chemical) | |
|---|---|---|
| Sanitizing method | Hot-water final rinse via booster heater | Chemical sanitizer in the final rinse |
| Electrical load | High; booster heaters are often the largest load | Lower |
| Ventilation | More heat and vapor; may need a hood or vapor/condensate system | Less heat and vapor |
| Ongoing costs | Energy for heating water | Sanitizer and other chemicals |
| Drying | Faster | Slower |
Water, ventilation and hood implications
Dish machines release heat and moisture. Depending on the machine type, sanitizing method and your local mechanical code, a high-temp machine (and some low-temp conveyors) may need a Type II hood over it or a machine with a built-in vapor-removal or condensate system. Ask your mechanical contractor and local code official before choosing; a machine that avoids a hood can change your ventilation budget..
Water quality matters too. Hard water leaves scale on heating elements, wash arms and wares, which raises chemical use and service calls. Many manufacturers recommend water treatment where hardness is high. At the scrapping station, a low-flow pre-rinse spray valve saves water; WaterSense labels commercial pre-rinse spray valves that meet its criteria.
Utilities to confirm before ordering
Get the spec sheet for the exact model and configuration, then confirm each utility with your contractors. Voltage and phase options change the electrical load, and a built-in booster adds to it.
Electrical: voltage, phase and amperage for the machine and any booster, and the disconnect location. Larger machines and boosters commonly need 208–240V or three-phase service. Water: hot-water supply temperature and flow, a separate cold supply if needed, pressure, and treatment. Drain: size, location and whether your local plumbing code routes the drain to a grease interceptor or prohibits it; rules vary. Space: dish tables, a scrapping area, rack storage and service access.
NSF/ANSI 3 and ENERGY STAR
NSF/ANSI 3 is the NSF standard for commercial warewashing equipment, covering sanitation design and sanitizing performance. Health departments generally expect a dish machine to be listed to NSF/ANSI 3 or an equivalent standard. Verify the listing in NSF's online database.
ENERGY STAR certifies commercial dishwashers, including high-temp and low-temp models across several machine types, that meet its energy and water criteria. Because dish machines run all day, efficiency can matter, and many utilities offer rebates on certified models.
Cost and quoting
In 2026 a new undercounter dishwasher typically costs $3,000–$9,000, a door-type machine $6,000–$18,000 and a rack conveyor $20,000–$60,000 or more, before freight, installation and tax. Booster heaters, dish tables and installation are extra. We sell new equipment only, shipped direct from the manufacturer or its distribution warehouse, and our sales team sends freight-included written quotes within one business day (Mon–Fri, 8am–6pm ET). We do not install; we coordinate delivery and can refer installers.
Assumptions and limitations
Rack-per-hour figures are typical capacity classes; the manufacturer's spec sheet for the exact model governs. Prices are typical 2026 U.S. ranges for new equipment, before freight, installation and tax. We deliberately omit specific sanitizing temperatures and chemical concentrations: the machine's data plate and your local health department govern, and local codes differ on hoods, drains and grease interceptors. This guide is compiled from manufacturer literature and the primary sources listed, not from our own testing.
Need help selecting equipment for your kitchen?
Request a personalized equipment quote. Our in-house sales team replies within one business day with freight-included pricing on new equipment from 135+ manufacturers and warehouses.
Frequently asked questions
What is the difference between a high-temp and a low-temp dishwasher?
A high-temp dishwasher sanitizes with a hot-water final rinse heated by a booster heater, while a low-temp dishwasher sanitizes with a chemical sanitizer. High-temp machines need more electrical capacity and may need vapor control; low-temp machines carry ongoing chemical costs.
How many racks per hour does a restaurant dishwasher wash?
Undercounter machines typically handle about 20–40 racks per hour and door-type machines about 50–70, while conveyors often reach 200 or more. Ratings are maximums under ideal conditions, so check the spec sheet and size with headroom.
Does a commercial dishwasher need a hood?
It depends on the machine and your local mechanical code. High-temp machines in particular may need a Type II hood or a built-in vapor-removal or condensate system, so confirm with your local code official before ordering.
What temperature does a commercial dishwasher need to sanitize?
The FDA Food Code sets minimum final-rinse temperatures for hot-water sanitizing machines, but the machine's data plate and your local health department govern. Follow the data plate and verify with a temperature-measuring device.
Do commercial dishwashers need to be NSF certified?
Most health departments expect commercial dish machines to be listed to NSF/ANSI 3 or an equivalent standard. Confirm with your local health department before you buy.
Sources
- FDA Food Code 2022 (U.S. Food and Drug Administration)
- NSF (standards and certification)
- NSF Certified Products Listings: Food Equipment
- ENERGY STAR Commercial Food Service Equipment
- WaterSense (U.S. EPA)
- International Codes, including the International Mechanical, Plumbing and Building Codes (International Code Council)
- NFPA 70, National Electrical Code (NFPA)
Related
- Kitchen Hood Types: Type I vs Type II, Styles and Ventless
- Commercial dishwashers
- Hoods and ventilation
- Three-compartment sink sizing
- Commercial kitchen electrical requirements
- NSF certification for restaurant equipment
- Request a quote
This guide is general information for planning and purchasing, not legal, engineering or code-compliance advice. Codes and their adopted editions vary by state and locality; confirm requirements with your health department, building official and licensed installers. Last reviewed on the date shown above.