Buying guide
Kitchen Hood Types: Type I vs Type II, Styles and Ventless
Who this is for: Restaurant owners, chefs and project teams planning a cook line, comparing hood options or preparing to talk with a mechanical contractor and the local code official.
Short answer: A Type I hood is used over cooking that produces grease or smoke, such as fryers, griddles, ranges and charbroilers, and includes grease filters, a grease duct and a fire-suppression system. A Type II hood handles heat, steam and vapor from appliances such as some ovens and dish machines. The hood style (wall canopy, island or backshelf), the exhaust and make-up air design and any ventless option all depend on your appliances and your local mechanical and fire code, and the authority having jurisdiction makes the final decision.
Type I vs. Type II hoods
The type of hood follows from what the appliances underneath produce. Grease-laden vapor is a fire risk, so appliances that produce it generally require a Type I hood with listed grease filters or extractors, a welded grease duct and a fire-suppression system. Appliances that produce heat, steam or odor without grease may need only a Type II hood, which removes heat and moisture and uses lighter duct construction.
Whether a particular appliance needs a hood, and which type, depends on the appliance's listing and your local code. Ask early, because adding a hood after the line is built is expensive.
| Type I | Type II | |
|---|---|---|
| Purpose | Capture grease and smoke | Remove heat, steam, vapor and odors |
| Typical appliances | Fryers, griddles, ranges, charbroilers, woks | Some ovens, steamers, dish machines |
| Grease filters | Required (listed filters or extractors) | Not for grease; may have condensate gutters |
| Fire suppression | Required | Not typically required |
| Duct | Liquid-tight grease duct with cleanouts | Lighter duct for heat and moisture |
Hood styles: wall canopy, island and backshelf
A wall canopy hood mounts against a wall over a line of appliances. It is the most common style and the most forgiving, because the wall blocks cross drafts and helps guide smoke into the hood.
An island hood hangs over a line of appliances that is open on all sides, such as a central cooking island or a display kitchen. Single-island hoods cover one line; double-island hoods cover two lines back to back. Because air can approach from every side, island hoods are more sensitive to drafts and generally need more exhaust airflow than a wall canopy over the same appliances.
A backshelf (proximity) hood mounts low and close to counter-height appliances such as griddles and countertop fryers. Being close to the cooking surface lets it capture effluent with less airflow, and it suits lower ceilings, but it is listed only for certain appliance types and heights and can limit the space above the cooking surface. Eyebrow hoods over oven doors are another specialized style.
Exhaust and make-up air basics
The exhaust fan pulls air, smoke and grease through the hood and duct and out of the building. The required airflow, measured in cubic feet per minute (CFM), depends on the hood style, its length and the duty of the appliances underneath: heavy-duty appliances such as charbroilers need much more exhaust than ovens. Listed hoods are tested for specific airflow ranges. Our kitchen hood CFM calculator gives a planning estimate; the hood manufacturer and your mechanical designer set the final number.
Every cubic foot exhausted has to be replaced. Make-up air units bring in outside air, which may be untempered or heated and cooled depending on climate. Without enough make-up air the kitchen goes negative: doors are hard to open, hoods capture poorly, pilot lights and burners can be affected, and the HVAC system works harder. Demand-control ventilation, which adjusts fan speed to cooking activity, can reduce energy use.
Fire suppression and fuel shutoff
A Type I hood is protected by a fire-suppression system, typically a wet-chemical system with nozzles over the appliances and in the hood plenum and duct. Systems for commercial cooking are commonly listed to UL 300. The system can activate automatically or from a manual pull station.
When the system discharges, it is interlocked to shut off the fuel supply to the protected appliances: a gas shutoff valve for gas equipment and power for electric equipment. Gas must not come back on until the system is reset. Suppression systems need regular inspection and service by a qualified company, commonly every six months, and nozzles may need to change when you add or move appliances. Ask your fire marshal which portable extinguishers are required near the line.
Ventless and recirculating options
Ventless (recirculating) hood systems filter grease, smoke and odor and return air to the kitchen instead of ducting it outside. They are commonly listed to UL 710B and typically include their own filtration and fire suppression. They can make cooking possible in spaces without a route for a grease duct, such as some leased or historic buildings.
The limits matter. A ventless system is listed for specific appliances and cooking loads, usually electric, and cannot be used with equipment outside its listing. Filters need frequent replacement, and the heat and humidity stay in the room, so the HVAC must handle them. Local approval is required, and some jurisdictions restrict ventless cooking. Some individual appliances are also listed for ventless use; the same approval applies.
Code basis and who decides
Hood requirements come from your local mechanical and fire codes, which are commonly based on the International Mechanical Code and NFPA 96, plus local amendments and the fuel gas code for gas appliances. The authority having jurisdiction, usually the building or mechanical official and the fire marshal, makes the final decision. Expect stamped drawings, permits and inspections.
We do not design, engineer or install hood systems. We sell new equipment, can quote hoods and appliances from your designer's or contractor's specification, coordinate delivery and refer installers. For typical installed costs by hood length and component, see our commercial kitchen hood cost guide.
Assumptions and limitations
This is general guidance, not a code interpretation. It intentionally omits code section numbers, clearance distances, overhang dimensions and specific airflow rates, because those depend on the hood listing, the appliances and the code adopted in your jurisdiction. Inspection intervals shown are common practice, not a requirement for your site. Your mechanical designer, fire-suppression contractor and the authority having jurisdiction decide what applies. This guide is compiled from the primary sources listed, not from our own testing.
Need help selecting equipment for your kitchen?
Request a personalized equipment quote. Our in-house sales team replies within one business day with freight-included pricing on new equipment from 135+ manufacturers and warehouses.
Frequently asked questions
What is the difference between a Type I and a Type II hood?
A Type I hood captures grease and smoke from appliances such as fryers, griddles and charbroilers and includes grease filters and fire suppression. A Type II hood removes heat, steam and vapor from appliances such as some ovens and dish machines.
Which hood style is best for a restaurant?
A wall canopy hood is the most common choice because the wall helps guide smoke into the hood. Island hoods suit open cooking lines but need more exhaust, and backshelf hoods suit low ceilings and counter-height appliances within their listing.
What is make-up air and why do I need it?
Make-up air is outside air brought in to replace the air the hood exhausts. Without it the kitchen goes under negative pressure, so hoods capture poorly, doors are hard to open and burners can be affected.
Does the fire-suppression system shut off the gas?
Yes, a hood fire-suppression system is interlocked to shut off fuel or power to the appliances under the hood when it discharges. Gas stays off until the system is reset.
Can I use a ventless hood instead of a Type I hood?
Sometimes, if a ventless system is listed for your specific appliances and your local code official approves it. Ventless systems are usually limited to certain electric appliances and need frequent filter changes.
Sources
- NFPA 96, Ventilation Control and Fire Protection of Commercial Cooking Operations (NFPA)
- International Codes, including the International Mechanical, Plumbing and Building Codes (International Code Council)
- NFPA 54, National Fuel Gas Code (NFPA)
- NFPA 70, National Electrical Code (NFPA)
Related
- Commercial Range Buying Guide: Width, Burners, Tops and Oven Bases
- Griddle vs. Charbroiler: Which Does Your Kitchen Need?
- Hoods and ventilation
- Kitchen hood CFM calculator
- Commercial kitchen hood cost
- Commercial fryer buying guide
- Gas vs. electric restaurant equipment
- Request a quote
This guide is general information for planning and purchasing, not legal, engineering or code-compliance advice. Codes and their adopted editions vary by state and locality; confirm requirements with your health department, building official and licensed installers. Last reviewed on the date shown above.