Commercial Refrigerator Buying Guide: Types, Sizes and Specs

By Equipment Specialist Team Last reviewed

Who this is for: Restaurant owners, chefs and managers buying or replacing reach-in, undercounter, prep-table or glass-door refrigeration for a commercial kitchen, bar or café.

Short answer: Pick the refrigerator type by where food is used: reach-ins for bulk back-of-house storage, undercounters and prep tables at the line, and glass-door merchandisers for customer-facing product. Then size by door count and cubic feet, choose a top-mount compressor for hot, greasy kitchens, and confirm the unit is listed to NSF/ANSI 7, the plug matches your outlet and there is room for ventilation. In 2026 a new 2-door reach-in typically costs $3,000–$8,000 before freight and tax.

The four main types and where each fits

Most kitchens end up with more than one type. A reach-in holds the bulk of the day's product, while undercounter units and prep tables keep ingredients within arm's reach of the cook so staff are not walking to the back on every ticket. Merchandisers are a front-of-house tool: they sell product, so they trade some efficiency for visibility.

If you are still deciding how much storage you need overall, start with a reach-in count and then add line refrigeration station by station. Kitchens that outgrow two or three reach-in doors often look at a walk-in cooler instead.

TypeBest forTypical price
1-door reach-inSmall kitchens, bars, cafés$2,000–$5,000
2-door reach-inMost full-service and QSR kitchens$3,000–$8,000
3-door reach-inHigh-volume kitchens, commissaries$5,000–$11,000
Undercounter / worktop (27–72 in.)Line stations, bars$1,500–$5,000
Sandwich / salad prep tableMake lines, delis, subs$2,000–$6,000
Pizza prep tablePizzerias$2,500–$7,000
Refrigerated chef baseUnder griddles and charbroilers$2,500–$7,500
Glass-door merchandiserGrab-and-go, beverages$1,500–$6,000
Common commercial refrigerator types. Typical 2026 U.S. street price for new equipment, before freight and tax. Ranges are broad because brand tier and options vary.

Door count and cubic-foot sizing

Reach-ins are sold by section, and each section is roughly one door wide. Typical figures are about 19–25 cu. ft. for a 1-section unit, about 40–50 cu. ft. for 2 sections and about 65–75 cu. ft. for 3 sections, but interior volume, shelf count and outside width vary by brand, so check the spec sheet. Half doors on the same cabinet reduce cold-air loss when staff open the unit often for small items.

A planning rule of thumb is roughly 1.5–2 cu. ft. of reach-in storage per meal served at peak, adjusted for how often you take deliveries. Most kitchens need at least one 2-door reach-in refrigerator as a baseline, plus undercounter units or a prep table at each line station.

Measure more than the floor. Check door openings, hallways, turns and elevator size on the delivery path, the door swing in front of the unit, and the ceiling height above a top-mount compressor. Many reach-ins are close to 80 in. tall or more on casters, so a low doorway can be a problem.

Solid vs. glass doors

Solid doors insulate better, hide clutter and generally use less energy, which is why they are the default for back-of-house storage. Glass doors let staff see stock without opening the door and let customers see product, which is the whole point of a merchandiser. Glass-door units usually use more energy than comparable solid-door units, and glass can fog in humid rooms. In a busy kitchen, glass doors can help with inventory checks, but they also show every messy shelf.

Top-mount vs. bottom-mount compressors

The compressor and condenser either sit on top of the cabinet or underneath it. Top-mount systems draw air from above, which tends to be cleaner and away from floor-level flour, grease and debris. Bottom-mount systems raise the lowest shelf to a more comfortable height, are easier for a technician to reach and are usually easier to clean, but they can pull in heat and dirt from the floor and from nearby cooking equipment.

Top-mountBottom-mount
Air drawn fromAbove the cabinetNear the floor
Hot, greasy cook lineOften the better choiceCan pull in heat and grease
Bakery or flour-heavy areasUsually preferredCondenser can clog with flour
Lowest shelf heightLowerHigher, easier to reach
Service accessNeeds a ladderEasier to reach
Overall heightTaller; check ceilingUsually shorter
General trade-offs. Placement in your kitchen matters as much as the design.

Stainless vs. aluminum construction

Stainless steel exteriors resist dents and look better over time; stainless interiors stand up to heavy cleaning and spills. Aluminum interiors and exteriors (often with galvanized or coated steel on the sides and back) cost less and are fine for many kitchens. A common compromise is a stainless front and doors with an aluminum interior. Ask which surfaces are stainless, because listings often describe only the doors. Our 304 vs. 430 stainless guide explains the difference between steel grades.

Refrigerant, NSF/ANSI 7 and ENERGY STAR

Hydrocarbon refrigerant R-290 (propane) is now common in new self-contained commercial refrigerators and freezers. It has a low global warming potential and good efficiency. It is flammable, so units are built with limited charge sizes, and service should be done by a technician trained on flammable refrigerants. The EPA's SNAP program lists which refrigerants are acceptable for which equipment; we do not list rule deadlines here because they vary by product type and have changed over time.

NSF/ANSI 7 is the NSF standard for commercial refrigerators and freezers. Most health departments expect food storage refrigeration to be listed to it or an equivalent sanitation standard, and you can verify a listing in NSF's online database. Note that some merchandisers are listed only for prepackaged or bottled product, not open food, so check the listing scope if you plan to store open food.

ENERGY STAR certifies commercial refrigerators and freezers that meet its efficiency criteria. Certified models typically cost a little more but use less energy, and many utilities offer rebates. Check energystar.gov for the current product list and your utility for rebates.

Electrical, clearance and ventilation

Most 1- and 2-door reach-ins run on 115V and ship with a NEMA 5-15P plug, but larger units, some freezers and some prep tables need a 5-20P plug or a different circuit. Check the spec sheet for voltage, amperage and plug type, and confirm the outlet before delivery. Many manufacturers call for a dedicated circuit; our commercial kitchen electrical requirements guide covers the basics.

Refrigeration rejects heat. Leave the clearance the manual calls for around the condenser intake and exhaust, keep the unit away from fryers, ovens and dish machines where you can, and clean the condenser coil on a regular schedule (often every 1–3 months). Blocked airflow and dirty coils are a leading cause of high cabinet temperatures and early compressor failure.

Warranty

Compressor coverage is often longer than parts and labor coverage: a common pattern is several years on the compressor and a shorter term on other parts and labor, but terms differ by manufacturer and model. Read what is excluded (condenser cleaning neglect, improper installation, glass), whether labor is included, and how to register the unit. We sell new equipment only, so the manufacturer's warranty applies from the start.

Assumptions and limitations

Prices are typical 2026 U.S. street prices for new equipment, before freight and tax, and individual quotes can fall outside them. Cubic-foot figures, plug types and warranty patterns are typical industry values, not guarantees for any model; the manufacturer's spec sheet governs. Refrigerant rules and health department requirements change and vary by location. This guide is compiled from manufacturer literature and the primary sources listed, not from our own testing.

Need help selecting equipment for your kitchen?

Request a personalized equipment quote. Our in-house sales team replies within one business day with freight-included pricing on new equipment from 135+ manufacturers and warehouses.

Get a Free Quote Call (732) 479-6550

Frequently asked questions

How much does a commercial refrigerator cost?

A new 2-door reach-in refrigerator typically costs $3,000–$8,000 in 2026, before freight and tax. One-door units typically run $2,000–$5,000 and 3-door units $5,000–$11,000, with value brands at the low end and premium stainless models at the high end.

How many cubic feet is a 2-door reach-in refrigerator?

A 2-door reach-in is typically about 40–50 cu. ft. Interior volume varies by brand and model, so check the spec sheet.

Is a top-mount or bottom-mount refrigerator better for a restaurant?

Top-mount compressors are usually better near hot cook lines and in bakeries because they draw cleaner, cooler air from above. Bottom-mount units are easier to service and raise the lowest shelf.

What plug does a commercial refrigerator use?

Most 1- and 2-door reach-ins use 115V with a NEMA 5-15P plug. Larger units and some freezers and prep tables need a 5-20P or other configuration, so check the spec sheet.

Do I need an NSF-listed refrigerator?

Most health departments expect commercial food refrigeration to be listed to NSF/ANSI 7 or an equivalent sanitation standard. Confirm with your local health department before you buy.

Sources

Related

This guide is general information for planning and purchasing, not legal, engineering or code-compliance advice. Codes and their adopted editions vary by state and locality; confirm requirements with your health department, building official and licensed installers. Last reviewed on the date shown above.